NIR-6300 HARSH-ENVIRONMENT ANALYZER

IMPROVE PROCESS CONSERVE ENERGY REDUCE WASTE ASSURE QUALITY
Performance in Challenging Environments
- IP67 and NEMA4x rated
- Tough #316 stainless-steel enclosure
- Withstands severe wash-downs
- Engineered to perform in the most demanding environments
- Performs in extreme temperatures up to 221 ͦ F (95 ͦ C)
- Non-contact, non-invasive, real-time results
- Continuous monitoring, precision measurement
INSTRUMENT DETAILS
NIR-6300 Online Moisture Analyzer | IP67 Harsh Environment Sensors
The IP67 rating of the NIR-6300 Series was developed to withstand severe wash-downs, excessive dust environments, and to protect it against the effects of immersion. Its rugged stainless steel enclosure makes it ideal for harsh environments, high temperatures, and aggressive mining and chemical applications.
IR Analyzer Options
The Harsh Environment Analyzer’s standard features include an integrated liquid or air vortex cooling system that is rated from 0°C to 85°C; additional options are available to exceed this operating range. A number of options, depending upon your specific application, are available contingent upon your environmental operating temperature and whether or not it is a food grade application.
Engineered Quality and Durability
Sensortech is unique in its ability to deliver dependable performance through its advanced IR technology, leading edge manufacturing processes, and comprehensive testing and quality control standards. An emphasis on durability had been placed on the NIR-6300 during its development in order to bring Sensortech’s high standard of performance to industrial applications.
Engineered for In-process Performance
- Innovative Optical Design
The NIR-6300 Harsh-Environment Analyzer optical design provides a foundation of measurement stability and reliability. High precision tolerances of machined parts and alignment of optical components ensure optimal performance. - Single-Point, Dual-Purpose Detector
The long established Quadrabeam Principle combines the measurement light path and the direct (prime) light path onto a single detector eliminating variations due to aging and operating temperature more effectively than expansive matched dual detector products. The large surface area detector (10mm sq.) minimizes error due to product height variation. - Collimated Energy Source
Effective use of power dramatically increases optical efficiency enabling the instrument to run significantly cooler. The reduced operating temperature inherently reduces stress on electronics and power supplies, increases the life of the instrument and further reduces costs associated with added temperature conditioning. - Optimized Electronic Signal Conditioning
Oversampling, 16-bit resolution and multiple-level digital filtering minimize
SPECIFICATIONS: NIR-6300 Harsh-Environment Analyzer
NUMBER OF MEASURED CONSTITUENTS: | 1, 2 or 3 | ||
RANGES AND ABSOLUTE ACCURACY:1 | Moisture | 0 to 95% ±0.10% | |
Fat | 0 to 75% ±0.20% | ||
Protein | 0 to 70% ±0.15% | ||
Total Sugar | 0 to 30% ±1.00% | ||
Nicotine | 0 to 6% ±0.10% | ||
INSTRUMENT REPEATABILITY: 2 | ±0.10 | ||
RECOMMENDED MEASUREMENT DISTANCE: | 4 to 12 in. (100 to 300 mm) | ||
STANDARD INSTRUMENT WEIGHT: 3 | 37 lbs (17 kg) | ||
OPTICAL SAMPLING SIZE: | 1.77 in (45 mm) | ||
OPERATING TEMPERATURES: 4 | Standard | 32 to 122°F (0 to 50°C) | |
Air Cooling Option | 32 to 167°F (0 to 75°C) | ||
Water Cooling Option | 32 to 203°F (0 to 95°C) | ||
Insulated with Water Cooling Option | 32 to 221°F (0 to 105°C) | ||
ENCLOSURE: | #316 Stainless Steel
IP67 Rated NEMA 4X Rated |
||
POWER: | 85/265VAC (47/63Hz), 25W | ||
Optional | 24 VDC, 25W |
Management Software
The NIR-6300 Harsh-Environment Analyzer includes a Sensortech Systems proprietary PC-based software package that offers a detailed view of your production process from a desktop or laptop computer.
Measurement display, data-logging, calibration utilities and network configurations are among the many features included with your NIR Series Management Software.
Easy integration with multiple communication protocols
Implementing continuous moisture measurement into your process is a simple task with the NIR-6300 Harsh-Environment Analyzer. We offer standard and proprietary options designed to integrate into your process control system.
STANDARD INSTRUMENT INTERFACE OPTIONS: | 3 self-powered isolated 4-20mA outputs | |
1 Ethernet TCP/IP | ||
1 Digital RS-485 or RS-422 or RS-232 | ||
1 Digital Input | ||
1 Digital Output | ||
PROPRIETARY INTERFACE OPTIONS:5 | PROFIBUS | |
PROFINET | ||
DeviceNet | ||
EtherNet IP |
Intelligent Inactive Display for Real-Time, Online Results
Our HMI-6000 interface to your IR Series Moisture Analyzer. It features a range of administrative controls, diagnostic tools, and moisture management settings that provide real-time access to your analyzers central functions while it is in operation. The HMI-6000 has a touch interface, color display and runs on a Windows CE operating system.
A single point connection to your NIR Series analyzer provides power and communication to your HMI-6000. This feature offers hassle free installation and easy setup.
NIR-6300 Standard Features and Alternative Configurations
We can custom build analyzers to fit your application and measurement requirements
NIR-6300 Standard Features | NIR-6300 Alternative Custom Configurations | |
|
NIR-6301 | Two Constituents |
NIR-6350 | Three Constituents | |
NIR-6360 | Internal Insulation for Extreme Ambient Temperatures
Three Constituents |
|
NIR-6370 | High Sensitivity Hardware | |
NIR-6371 | High Sensitivity Hardware
Two Constituents |
|
NIR-6375 | High Sensitivity Hardware
Three Constituents |
|
NIR-6380 | Tobacco-grade Configuration |
APPLICATIONS FOR THE NIR-6300 HARSH-ENVIRONMENT ANALYZER
- Bauxite
Boric Acid
- Sodium Carbonate
Ceramics
You may be interested in…
CONTACT US
341 Bernoulli Circle
Oxnard, CA 93030
United States of America
Email us: info@sensortech.com
Phone: (805) 981-3735
Fax: (805) 409-4833
INTERNATIONAL
BUSINESS HOURS
8:00 am – 4:30 pm PST
Saturday – Sunday: Closed