NIR-6400 EXPLOSION-PROOF ANALYZER

IMPROVE PROCESS CONSERVE ENERGY REDUCE WASTE ASSURE QUALITY
Class I, Div 1 Protection
- Heavy cast metal enclosure designed for Class I Div 1 environments
- Designed to withstand environments with flammable gases or vapors, combustible dust and easily ignitable fibers exist.
- Class I, II hazardous locations as defined by National Electrical Code
- Performs in extreme temperatures up to 221 ͦF (95 ͦC)
- Rugged and durable, built for demanding high temperature plant conditions
INSTRUMENT DETAILS
Extreme Level of Protection
The NIR-6400 Explosion Proof moisture analyzers provide an advanced level of protection from hazardous environments and meet the compliance standards of most regulatory bodies. The NIR-6400 Series is suited for Class I, II, and III hazardous locations, as defined by the National Electrical Code®, and is accompanied with the appropriate certificates required of the classification including the nameplate indicating the distinct classification for which it has been approved.
Sensortech’s NIR-6400 Series of Explosion Proof moisture analyzers satisfy a unique manufacturing requirement in hazardous environments where flammable gases or vapors, combustible dust, and easily-ignitable fibers are present. We are specialists in these sensitive manufacturing environments and provide quality performance where it is needed most.
Harsh Environments:
- Extreme Temperatures
- Excessive Dust and Debris
Hazardous Locations:
- Flammable Gasses, Mists or Vapors
- Combustible Dust or Fibers
- Explosive or Ignitable Fibers
Engineered for In-process Performance
- Innovative Optical Design
The NIR-6400 Explosion-Proof Analyzer optical design provides a foundation of measurement stability and reliability. High precision tolerances of machined parts and alignment of optical components ensure optimal performance. - Single-Point, Dual-Purpose Detector
The long established Quadrabeam Principle combines the measurement light path and the direct (prime) light path onto a single detector eliminating variations due to aging and operating temperature more effectively than expansive matched dual detector products. The large surface area detector (10mm sq.) minimizes error due to product height variation. - Collimated Energy Source
Effective use of power dramatically increases optical efficiency enabling the instrument to run significantly cooler. The reduced operating temperature inherently reduces stress on electronics and power supplies, increases the life of the instrument and further reduces costs associated with added temperature conditioning. - Optimized Electronic Signal Conditioning
Oversampling, 16-bit resolution and multiple-level digital filtering minimize
NIR-6400 Explosion-Proof Analyzer Specifications
|
Management software for monitoring and controlling process
The NIR-6400 Explosion-Proof Analyzer includes a Sensortech Systems proprietary PC-based software package that offers a detailed view of your production process from a desktop or laptop computer.
Measurement display, data-logging, calibration utilities and network configurations are among the many features included with your NIR Series Management Software.
Easy integration with multiple communication protocols
Implementing continuous moisture measurement into your process is a simple task with the NIR-6100. We offer standard and proprietary options designed to integrate into your process control system.
STANDARD INSTRUMENT INTERFACE OPTIONS: | 3 self-powered isolated 4-20mA outputs | |
1 Ethernet TCP/IP | ||
1 Digital RS-485 or RS-422 or RS-232 | ||
1 Digital Input | ||
1 Digital Output | ||
PROPRIETARY INTERFACE OPTIONS:5 | PROFIBUS | |
PROFINET | ||
DeviceNet | ||
EtherNet IP |
Intelligent Inactive Display for Real-Time, Online Results
Our OI-6000 interface to your IR Series Moisture Analyzer. It features a range of administrative controls, diagnostic tools, and moisture management settings that provide real-time access to your analyzers central functions while it is in operation. The OI-6000 has a touch interface, color display and runs on a Windows CE operating system.
A single point connection to your NIR Series analyzer provides power and communication to your OI-6000. This feature offers hassle free installation and easy setup.
Custom engineered to fit your manufacturing need and environment
We can custom build analyzers to fit your application and measurement requirements
NIR-6400 Standard Features | NIR-6400 Alternative Custom Configurations | |
|
NIR-6401 | Class 1 Div 1 Classification
Two Constituents |
NIR-6410 | Class 2 Div 1 Classification
Air pressurization panel |
|
NIR-6411 | Class 2 Div 1 Classification
Air pressurization panel Two Constituents |
|
NIR-6450 | Three Constituents | |
NIR-6457 | High Sensitivity Hardware
Three Constituents (6 filter – Two Constituents) |
|
NIR-6467 | High Sensitivity Hardware
Air pressurization panel Three Constituents |
APPLICATIONS FOR THE NIR-6400 EXPLOSION-PROOF ANALYZER
- Minerals
Magnesium
Coal
Carbon
Charcoal
Coke Dust
- Chemicals
- Building Materials
- Food
Flour
Grain
You may be interested in…
CONTACT US
341 Bernoulli Circle
Oxnard, CA 93030
United States of America
Email us: info@sensortech.com
Phone: (805) 981-3735
Fax: (805) 409-4833
INTERNATIONAL
BUSINESS HOURS
8:00 am – 4:30 pm PST
Saturday – Sunday: Closed